Steam sterilizers model STAB 07

    Designed for sterilizing instruments, glassware and ustensils and for sterilization of culture media, infected waste, liquids. Applications include also polymerization and forced ageing.
 

Construction and operating features:

 -  Fitted with time-temperature controller with microprocessor,
 -  Fully automatic,
 -  Temperature rise time: from 15 min to 65 min,
 -  Digital display with a resolution of 1°C,
 -  Temperature plateau: adjustable, from 1 to 9999min,
 -  Power consumption during temperature plateau (132°C): 45% of maximum power,
 -  Cycle completion acoustically signaled,
 -  Front loading,
 -  Equipped with one stainless steel shelf,
 -  Water volume: 0.50 liters.
 

Technical data:

- Model STAB 7
- Capacity (liters)
- Temperature range  121-135 °C
- Precision at set temperature  1 °C
- Chamber  160 x 365 mm (Ø x D)
- Overall  350 x525 x235 mm
- Voltage 220  V / 50 Hz
 
  

 DENTAL FURNACES

 models: CD 1020,
                 CD 1011, CD 1111, CD 1016,
                 CD Microterm.
 
 Advantages:
 -  easy operation,
 -  low power consumption,
 -  high reliability due to the quality of materials and components:
 -  KANTHAL (Sweden) heating elements,
 -  RATH (Austria) ceramic insulation,
 -  INTEL-USA microprocessor,
 -  UE electronic components,
 -  digital and optical display of time and temperature and of the actual state,
 -  adjustment and display precision: 1 digit,
 -  multiple possibilities of programming: prestart, with/without preheating, temperature ramp rate, set temperature, time of temperature holding in plateau, acoustical and optical signal at the end of the program,
 -  fan assisted evacuation of water steam and/or dental wax,
 -  multiple protections: against thermocouple failure, overheating, power element supply failure,
 -  service during the warranty period and afterwards,
 -  spare parts provided 10 years after purchasing,
 -  warranty period: 24 month since delivery.
 


Technical data:
           
Model*Max. temp.[°C]*Precision at set temp.[°C]*Power[W]*Volume[liters]*dim(DxWxH)

mCD             *  1.000   *   ± 5 oC  *     800   *   2   *   155x120x75  *  5 prog.
CD 1011        *  1.000   *   ± 3 oC  *  1.400   *   3   *   160x180x110  *  5 prog.
CD 1011 M    *  1.000   *   ± 1 oC  *  1.400   *   3   *   160x180x110  *  10 prog.
CD 1111        *  1.100   *   ± 3 oC  *  1.750   *   3   *   160x180x110  *  5 prog.
CD 1111 M    *  1.100   *   ± 1 oC  *  1.700   *   3   *   160x180x110  *  10 prog.
CD 1016         *  1.150   *   ± 3 oC  *  2.000   *  6   *   170x280x115  *  5 prog.
CD 1016 M    *  1.150   *   ± 1 oC  *  2.000   *   6   *   170x280x115  * 10 prog.

 

Notes:
 
 a) The five programs common to the mCD. CD 1020, CD 1011, CD 1111, CD 1016 models are:
 1.Programme no. 1 (P1): preheating (325 °C), preheating temperature holding (20 min. at 325°C). temperature rise to the final set temperature.
 2.Programme no. 2 (P2): preheating (325 °C) without preheating temperature holding, and temperature rise to the set temperature.
 3.Programme no. 3 (P3): full power temperature rise to the set temperature.
 4.Programme no. 4 (P4): preheating, (325 °C), preheating temperature holding, full power temperature rise to the set temperature.
 5.Programme no. 5 (P5): preheating, (325 °C), preheating temperature holding, temperature rise to the set temperature with 70% of the maximum rated power
 b) The controller Microterm, model M, increases the programming possibilities to 10, also including the prestart option, the temperature ramp rate, the temperature in plateau, the duration of the plateau and the acoustical signal at the end of the program.
 




PORCELAIN FURNACE, model uPC
 

 Advantages:

 -  Easy to program and operate,
 -  Help menu for each program,
 -  Fitted with controller with microprocessor
 -  Easy to read LCD display, with the possibility of assigning a name to each program (ex: Oxidation, Dull, etc),
 -  Graphical display of the firing cycles, consisting of 3 ramps and 2 plateaus with adjustable ramp rate and plateau duration,
 -  Mobile firing platform,
 -  Vacuum pump included.
 


 

Type

Temp. max. [°C]

Precision [oC]

Power [W]

Volume [litri]

Dimensions interior (lxLxH) [mm

Obs.

mCD

1.000

± 5 oC

800

155x120x75

5 prog.

CD 1020

1.000

± 5 oC

1.200

120x140x120

5 prog.

CD 1011

1.000

± 3 oC

1.400

160x180x110

5 prog.

CD 1011 M

1.000

± 1 oC

1.400

160x180x110 

10 prog.

CD 1111

1.100

± 3 oC

1.750

160x180x110 

5 prog.

CD 1111 M

1.100

± 1 oC

1.700

160x180x110 

10 prog.

CD 1016

1.150

± 3 oC

2.000

170x280x115 

5 prog.

CD 1016 M

1.150

± 1 oC

2.000

170x280x115

10 prog.



  Technical data:

 -  Overall dimensions (DxWxH) [mm] 240x265x580
 -  Inside dimensions [mm] Ø 90height 65
 -  Volume [dm³] 0.4
 -  Useful volume [dm³] 0.25
 -  Elevator travel [mm] 123
 -  Maximum temperature [°C] 1200
 -  Precision at set temperature [°C] 1
 -  Temperature display resolution [°C] 1
 -  Number of programs 40
 -  Weight [kg] 25
 -  Voltage [V] 220/50Hz
 

  
SANDBLASTER, model SAB
Purpose: for abrasive cleaning and finishing of metal dental appliances.
 
  
  
MICRO SANDBLASTER, model µSAB
Purpose: for abrasive cleaning, polishing and preparation of dental appliances (with   Al2O3 grains of 50 or 120 µm).
 
 
  
PRESSURE STEAM MACHINE, model SUPER JET
Designed for cleaning models, removing polishing compounds from crowns, bridges, cleaning extraneous wax from denture casts, debris removal.
 
  
  
CASTING MACHINES
Designed for dental casting , proven centrifugal casting technique with state-of-the-art high-frequency melting device.
Easy handling and excellent accessibility, thanks to drawers with very compact dimensions.
Economical use of casting alloys, rapid melting up to 1550 °C.


Technical data
- Rated voltage: 220V, 50/60Hz
- Consumption: approx. 16A
- Melting power: 2.6kW, 100KHz
- Water supply and discharge: 2 lt/min
- Dimensions (HxWxD): 340x560x560 mm
- Weight: 60kg

  
WAX POTS
Designed for maintaining the wax at the constant required temperature with two choices: potentiometric adjustment of temperature or digital control and display of the set temperature.
Range of temperature: 40-120 °C
 
 
  
BUNSEN BURNERS
 -  overall height 110mm,
 -  burner tube 8 mm inner diameter.
 
  
  
ELECTRIC WAX KNIFE
Designed for wax shaping with potentiometric adjustment of the desired work temperature.
 
  

PRESSURE POLYMERIZATION APPARATUS, model BARO2000
Designed for use in dental laboratories for acrylics and composites polymerization under pressure : Chromasit-IVOCLAR, Superpont and Superpont C+B, Superacril and Duracril-SPOFA, Biodent K+B-de TREY.
 

 Technical data:

 -  voltage: 220/50 Hz,
 -  maximum power rate: 350W,
 -  power consumption in plateau: 45% of max power rate,
 -  Range of operating temperature: 20°C-130°C,
 -  Precision at set temperature: 1%,
 -  Range of operating pressure: 0 bar- 8 bar,
 -  Useful dimensions of pressure chamber: Ø 100mm, height 120mm,
 -  fitted with time-temperature controller, with microprocessor,
 -  Digital display of time and temperature, with a resolution of 1°C/min,
 -  rise time to the set temperature: variable, according to the set diagram and the load,
 -  fitted with a system for forced water cooling of the chamber,
 -  Weight:15 kg.
 

 

Noutati

Acum sterilizatoarele cu abur tip STAB 49 au un design imbunatatit!!